Greenlee HK1240 and HK1240C Hydraulic Crimping Tools Instruction Manual

This manual provides instructions for the safe operation, troubleshooting, and repair procedures for the Greenlee HK1240 and HK1240C Hydraulic Crimping Tools.


Greenlee HK1240 and HK1240C Hydraulic Crimping Tools Instruction Manual - cover page
Brand
Greenlee
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
509 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
625C37B4FB466B560FDE4BDE54936597

About this manual

The Greenlee HK1240 and HK1240C are handheld, self-contained hydraulic crimping tools designed to crimp aluminum and copper connectors onto electrical cable. The HK1240C features a PVC-covered crimping head. These tools utilize industry-standard 12-ton U-type dies, which are purchased separately.

The manual covers essential safety information, including warnings about electric shock, skin injection from hydraulic oil, and the risks of incomplete crimps. It details the tool's identification, specifications, and step-by-step operation procedures for die installation and crimping. Additionally, it provides charts for die selection and connector compatibility for both copper and aluminum applications.

What's inside

  • Description
  • Safety
  • Identification
  • Specifications
  • Operation
  • Die Selection
  • Connector Selection
  • Periodic Pressure Relief Valve Check

Specifications

Crimping Force106 kN (12 tons)
Crimping Range8 AWG to 750 kcmil
Tool Length552 mm (21.75")
Width74 mm (2.9")
Mass/Weight6.1 kg (13.4 lb)
Hydraulic Oil50 ml (0.1 pint)

Frequently asked questions

What materials can the HK1240 and HK1240C crimp?

The tools are intended to crimp aluminum and copper connectors onto electrical cable.

What is the crimping force of the tool?

The tool operates with a crimping force of 106 kN, which is equivalent to 12 tons.

How do you know if a crimp is complete?

A completed crimp is indicated by the handle load dropping suddenly, often accompanied by an audible 'pop' when the pressure relief valve activates.