This manual introduces the safe use and maintenance methods of Greenlee H4802, H4802-1, and H4802-6 pole tampers.
This service manual provides instructions for the safe servicing of Greenlee H4802, H4802-1, and H4802-6 pole tampers. It details safety precautions regarding hydraulic pressure and skin injection hazards, and outlines the proper procedures for disassembling and reassembling the tool components.
The H4802 corresponds to serial codes FKA and FZP, the H4802-1 corresponds to FKM and FZR, and the H4802-6 corresponds to FKF and FZT.
The machine screws must be torqued to 3.5 Nm (31 in-lb).
Apply a thread sealant, such as Loctite 242 Threadlocker, to the threads of the screws.