This file is an Indiana residential wastewater treatment system operation and maintenance manual
This manual provides detailed instructions for operating and maintaining Fuji Clean’s CE and CEN residential wastewater treatment systems. It covers installation procedures, system components, treatment processes, scheduled maintenance, inspection checklists, and troubleshooting. The document also outlines compliance requirements with Indiana State Department of Health rules and includes technical specifications for each model. Fuji Clean USA is the manufacturer, and the manual references its authorized representatives and technical support resources.
| Blower Size and Power Consumption | MAC80R 2.8 CFM, 1.27 kWh/day for CE5; MAC100R 3.5 CFM, 1.92 kWh/day for CE10 |
|---|---|
| Tank Material | Fibre-reinforced plastic |
| Tank Height (CE10) | 73.6 inches |
| Volume (CEN10) | 1498 gallons |
The manual covers Fuji Clean CE and CEN Models, including CE5, CE7, CE10, CEN5, CEN7, and CEN10.
The treatment process is a 'contact filtration' method involving anoxic and aerobic chambers with proprietary media for biological digestion and mechanical filtration.
Transfer the scum to Chamber 1 using a pump, ladle, or suitable container, and increase the recirculation rate within normal operating range.