SECO® DC Drives Bronco II 160 Series, 1/4 - 2 H.P. DC Drive 115/230 VAC 1 Phase, 50/60 Hz Input Installation & Operation Manual

This manual introduces the general information, installation, operation and other information of SECO® DC Drives Bronco II 160 series 1/4 - 2 H.P. DC Drive 115/230 VAC 1 Phase, 50/60 Hz Input.


SECO® DC Drives Bronco II 160 Series, 1/4 - 2 H.P. DC Drive 115/230 VAC 1 Phase, 50/60 Hz Input Installation & Operation Manual - cover page
Brand
SECO
Document type
Installation Guide
Language
English
Pages
28
File format
PDF
File size
459 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
43DC13D671C6B4D8337D054B89AE0D0E

About this manual

This manual provides step-by-step instructions for installing and operating SECO’s Bronco II 160 Series DC drives. It covers mounting requirements, electrical connections, wiring diagrams, and control settings for various models. Safety warnings are included for proper handling and installation. Troubleshooting guidance and replacement parts lists are also provided.

The controller converts AC line voltage to adjustable DC voltage to control shunt wound or permanent magnet DC motors. Models vary in enclosure type and control features, including speed and torque adjustment, forward/reverse switching, and remote operation options.

What's inside

  • General Information
  • Installation
  • Operation
  • Troubleshooting
  • Replacement Parts List
  • CE Compliance

Specifications

Horsepower Range1/4 - 1 HP at 115 VAC; 1/2 - 2 HP at 230 VAC
AC Line Input Voltage115 or 230 VAC ±10%
AC Line Frequency50/60 Hz ±2 Hz
Service Factor1.0
DutyContinuous
Max Load Capacity150% for 1 min.
Ambient Temperature (Chassis)0-55°C
Relative Humidity5-95% non condensing
Altitudeto 3300 ft. (1000m)
Speed Range (Armature Feedback)30:1
Speed Regulation (Armature Feedback)±2%
Current Range2.5, 5, 7.5, 10 Amps DC Nominal (Adjustable to 150% each range)
Max Speed75 - 110% of motor base speed
Min Speed0 - 30% of Motor Base Speed

Frequently asked questions

What voltage and frequency does the Bronco II 160 Series support?

It supports 115 VAC or 230 VAC at 50/60 Hz ±2 Hz.

What is the maximum load capacity for continuous duty?

It can handle 150% load for 1 minute.

What are the ambient temperature limits for chassis and enclosed models?

Chassis models: 0-55°C; Enclosed models: 0-40°C.

What is the speed regulation with armature voltage feedback?

It is ±2% for 95% load change.