This manual introduces the general information, installation, operation and other information of SECO® DC Drives Bronco II 160 series 1/4 - 2 H.P. DC Drive 115/230 VAC 1 Phase, 50/60 Hz Input.
This manual provides step-by-step instructions for installing and operating SECO’s Bronco II 160 Series DC drives. It covers mounting requirements, electrical connections, wiring diagrams, and control settings for various models. Safety warnings are included for proper handling and installation. Troubleshooting guidance and replacement parts lists are also provided.
The controller converts AC line voltage to adjustable DC voltage to control shunt wound or permanent magnet DC motors. Models vary in enclosure type and control features, including speed and torque adjustment, forward/reverse switching, and remote operation options.
| Horsepower Range | 1/4 - 1 HP at 115 VAC; 1/2 - 2 HP at 230 VAC |
|---|---|
| AC Line Input Voltage | 115 or 230 VAC ±10% |
| AC Line Frequency | 50/60 Hz ±2 Hz |
| Service Factor | 1.0 |
| Duty | Continuous |
| Max Load Capacity | 150% for 1 min. |
| Ambient Temperature (Chassis) | 0-55°C |
| Relative Humidity | 5-95% non condensing |
| Altitude | to 3300 ft. (1000m) |
| Speed Range (Armature Feedback) | 30:1 |
| Speed Regulation (Armature Feedback) | ±2% |
| Current Range | 2.5, 5, 7.5, 10 Amps DC Nominal (Adjustable to 150% each range) |
| Max Speed | 75 - 110% of motor base speed |
| Min Speed | 0 - 30% of Motor Base Speed |
It supports 115 VAC or 230 VAC at 50/60 Hz ±2 Hz.
It can handle 150% load for 1 minute.
Chassis models: 0-55°C; Enclosed models: 0-40°C.
It is ±2% for 95% load change.