AWP® Super Series Operation Manual, Introduces the machine's operation methods, maintenance methods, safety precautions, etc.
This is the official operation manual for the Genie AWP® Super Series, designed for users and operators. It includes safety guidelines, operational procedures, maintenance instructions, and technical specifications. The manual emphasizes user safety, training requirements, and proper machine usage. It is intended to be kept with the machine at all times and is updated to the Fifth Edition, Second Printing, dated February 2022.
The manual covers topics such as hazard symbols, general safety, platform and ground controller operations, maintenance checks (including hydraulic fluid and air line lubricant levels), battery charging, transport, and specifications for various models in the series (AWP-20S to AWP-40S). This manual is written in Chinese.
| Maximum Working Height | AWP-20S: 26 ft 1 in / 8.0 m; AWP-25S: 30 ft 9 in / 9.4 m; AWP-30S: 35 ft 6 in / 10.8 m; AWP-36S: 42 ft 5 in / 12.9 m; AWP-40S: 46 ft 3 in / 14.1 m |
|---|---|
| Platform Maximum Height | AWP-20S: 20 ft 1 in / 6.1 m; AWP-25S: 24 ft 9 in / 7.5 m; AWP-30S: 29 ft 6 in / 9.0 m; AWP-36S: 36 ft 6 in / 11.1 m; AWP-40S: 40 ft 3 in / 12.3 m |
| Weight | See serial number label |
| Maximum Wheel Load | 509 lbs / 231 kg |
| Maximum Leg Load | 400 lbs / 181 kg |
| Load Capacity | AWP-20S, 25S, 30S, 36S: 350 lbs / 159 kg; AWP-40S: 300 lbs / 136 kg |
| Power | DC: 12V; AC: 110V or 220V; Pneumatic: 100 psi / 6.9 bar @ 80 cfm / 37760 cc/sec |
| Operating Temperature | -20 °F to 135 °F (-29 °C to 57 °C) |
| Noise Level | Ground work area: <70 dBA; Platform work area: <70 dBA |
The load capacity for the AWP-36S model is 350 lbs (159 kg).
The hydraulic oil specification is Chevron Rando HD or equivalent.
The operating temperature range is -20 °F to 135 °F (-29 °C to 57 °C).