This document introduces the operation and maintenance instructions for Accubar ® Constant Flow Bubble Gauge/Recorder 56-0133
This manual provides detailed instructions for operating and maintaining the Sutron Accubar Constant Flow Bubble Gauge/Recorder (model 56-0133-25-1). It covers setup procedures, cabling, sensor calibration, logging, and troubleshooting. The device measures water levels using bubble gauge principles and can operate standalone or connected to loggers via SDI-12, RS232, or RS485. It includes a front panel for configuration and data viewing, and features a built-in log for 300,000 readings. Maintenance sections cover desiccant replacement, leak testing, and firmware upgrades.
| Electrical Power Required | 8-16VDC |
|---|---|
| Average Power | <100 mW for a 3 second measurement every 15 minutes, no purge. |
| Pump on current | 4 Amp max, 2.5 Amp typical |
| Outputs | SDI-12, RS232, RS485 |
| Pneumatic Pressure Range | 0-25 psi |
| Accuracy | 0-25ft 0.02%FSO, 26-50 ft. 0.05% reading. |
| Resolution | 0.0001 psi |
| Purge Pressure | >=50 psi |
| Enclosure | NEMA-4 Fiberglass |
| Dimensions | 12” x 15” x 7.5” |
| Environmental Temperature | -25°C to +60°C optional -40°C to +60°C |
| Humidity | 0-95% Non-condensing |
The pneumatic pressure range is 0-25 psi.
Accuracy is 0.02% FSO for 0-25 ft and 0.05% reading for 26-50 ft.
It supports SDI-12, RS232, and RS485 interfaces.
The device requires 8-16VDC, with a typical pump current of 2.5A.