ecom instruments Ex-MX4 BT Infrared Thermometer Operating Instructions

This manual describes the functional description and operating instructions of the Ex-MX4 BT.


ecom instruments Ex-MX4 BT Infrared Thermometer Operating Instructions - cover page
Brand
Ecom Instruments
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
27
File format
PDF
File size
613 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
FF78AD919DA88C4988B94C2429499757

About this manual

The ecom instruments Ex-MX4 BT is a contactless temperature measuring device designed for industrial use in potentially explosive areas of Zones 1 and 2. It features an integrated Bluetooth module for data transfer and includes a 3-point laser marking system for precise measurement spot indication. The device operates using a laser beam (Class 2) and measures temperatures within a range of -30°C to +900°C.

What's inside

  • Application
  • Safety instructions
  • Errors and load restrictions
  • Ex data
  • Technical specifications
  • Bluetooth configuration
  • Functional description
  • Operation
  • Display screen
  • Settings

Specifications

Measuring range-30°C ... +900°C
Display resolution0.1°C
Accuracy± 0.75% of the measured value or ± 0.75 K
Response time250 ms (95%)
Optical resolution60:1
Emissivity range0.10 ... 1.50
Dimensions200 x 170 x 50 mm
WeightApproximately 600 g

Frequently asked questions

Which zones is the Ex-MX4 BT approved for?

The device is approved for use in potentially explosive areas of Zones 1 and 2.

What is the preset emissivity value?

The preset emissivity value is 0.95.

Can the device be used in Zone 0 areas?

No, the device must not be brought into Zone 0 areas.

Download PDF (613 KB)