About this manual

This manual provides instructions for installing and operating the WhisperKOOL Ceiling Mount Twin cooling system, designed for wine cellar temperature control. It includes details on electrical requirements, insulation, thermostat setup, and maintenance. The system uses R-134a refrigerant and is rated for 115V operation. Warranty registration and technician installation are required for warranty activation.

The manual also covers troubleshooting, maintenance schedules, and safety precautions, including insulation requirements and proper ventilation to avoid condensation and water damage.

What's inside

  • Introduction
  • Before You Start
  • Receiving & Inspecting the System
  • Quick Reference Guide
  • Display Layout & Unit Specifications
  • Preparing the Wine Cellar
  • Liquid-Measuring Thermostat (Bottle Probe)
  • System Operation
  • Controller Functions
  • WhisperKOOL Troubleshooting Guide

Specifications

Model9000 Evaporator (Fan Coil Unit)
Cellar SizeApprox. 3000 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier*
BTU/h8500
Dimensions35.75”L x 14.5”W x 12.75”H (x2)
RefrigerantR-134a
Voltage Rating115V
Weight90 lbs (per unit)
Amps1 running amp (per unit)
Line SetLiquid line: 3/8”; suction line 3/4” (less than 50 ft.), 7/8” (more than 50 ft.)
Drain Line1/4” ID clear plastic tubing (not provided)
WarrantyTwo-year limited warranty (parts and labor)

Frequently asked questions

What is the WhisperKOOL Cooling System?

The WhisperKOOL cooling system is a specialized refrigeration system designed for one purpose only: to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines.

What voltage does the system require?

The evaporator units require a dedicated 115V, 10-amp circuit. The condensing unit requires a dedicated 230V, 15-amp circuit.

Is a warranty active immediately after installation?

No, the warranty is not active until a warranty checklist has been received, reviewed, and approved.

What is required for proper insulation?

The evaporator unit (fan coil unit) must be insulated using the insulation blanket provided in accordance with this manual. Additionally, fiberglass insulation (R19 or higher) is required in the cavity between the ceiling joists.