PLATINUM SPLIT TWIN OWNER’S MANUAL
This manual provides instructions for installing and operating the WhisperKOOL Platinum Split Twin cooling system, designed for wine storage. It includes specifications for wall-mounted and fully ducted evaporator units, wiring and drainage requirements, and warranty information. The system maintains a 55°F cellar temperature with a 110°F ambient limit. Installation must be performed by a certified HVAC-R technician, and a drain line is required for each unit. The manual also includes troubleshooting and maintenance guidelines.
| Cellar Size | Approx. 3000 cu. ft. |
|---|---|
| BTU/h | 8500 |
| Voltage Rating | 115V |
| Refrigerant | R-134a |
| Temperature Setting | 55°F |
| Warranty | Two-year limited warranty |
A specialized refrigeration system designed to maintain optimal temperature and humidity for wine storage.
Each evaporator unit requires a 115V, 15-amp circuit; the condensing unit requires a 230V, 15-amp circuit.
Two-year limited warranty covering parts and labor.
A certified HVAC-R technician is required for installation.