This manual provides maintenance and operating instructions for air operated double diaphragm pumps.
This service and operating manual covers the installation, maintenance, and operation of the BLAGDON HG-CF-1090 air-operated double diaphragm pump. It includes safety warnings, technical data, performance curves, troubleshooting, and warranty information. The pump is ATEX certified for use in potentially explosive atmospheres and is designed for high-pressure applications with a 1:1 ratio diaphragm action. Proper installation and fluid compatibility are critical for safe and efficient operation.
The manual provides detailed guidance on mounting, air pressure settings, fluid compatibility, and exhaust handling. It also includes a parts list, assembly drawing, and technical specifications for materials and operating temperatures. Safety precautions are emphasized, including warnings about hazardous fluids, proper grounding, and the need for clean, dry air to prevent damage.
| Max Capacity | 18 Litres/Minute (3.9 Gallons/Minute) |
|---|---|
| Max Working Pressure | 8.6 Bar (125 psi) |
| Pump Weight | 4.0 Kg |
| Wetted Components Material | 316L Stainless Steel |
The maximum working pressure is 8.6 Bar (125 psi).
The wetted components are made of 316L stainless steel.
The maximum discharge head is 88 meters (289 feet).