About this manual

The document serves as a service and operating guide for the BLAGDON B50 and X50 Hygienic Series air operated double diaphragm pumps. It details the principle of operation, installation requirements including mounting orientation and pressure regulations, and important safety warnings regarding hazardous fluids and suction inlets.

What's inside

  • Service / Maintenance Log
  • Dimensions
  • Performance Curve
  • Technical Data & Temperature limitations
  • Explanation of Pump Nomenclature
  • Principle of Pump Operation
  • Installation guide
  • Important Warnings & Safety Information
  • Troubleshooting
  • Wet-side Overhaul

Specifications

Maximum Working Pressure8.6 Bar (125 psi)
Wetted Components Material316L Stainless Steel
Non-Wetted Components MaterialNickel Plated Aluminium
Valve Seats MaterialEPDM (Food Grade)

Frequently asked questions

What is the maximum working pressure of the B50 and X50 pumps?

The maximum working pressure for these pumps is 8.6 Bar or 125 psi.

What material are the wetted components made of?

The wetted components are constructed from polished 316L Stainless Steel.