UM2510 user manual

UM2510 user manual is a guide to using the VL53L1X ultra lite driver (ULD).


UM2510 user manual - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
User Manual
Language
English
Pages
27
File format
PDF
File size
623 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
9CA48583823B554BD11213DB029A941E

About this manual

The document provides an introduction to the VL53L1X Ultra Lite Driver (ULD), an optimized version of the initial driver with a smaller code footprint. It details the system overview, which consists of a hardware module and the software driver running on a host to control the sensor and retrieve ranging data.

The manual covers the functional description of ranging operations, including distance ranging and distance threshold detection. It outlines the mandatory and optional API functions required to initialize the sensor, configure timing budgets, set distance modes, and manage interrupts for data retrieval.

What's inside

  • Introduction
  • Acronyms and abbreviations
  • VL53L1X system overview
  • Ranging API functional description
  • API function call flow
  • Mandatory functions
  • Optional functions
  • Setting distance mode
  • Setting threshold and detection mode
  • Ranging example pseudo code

Specifications

Code footprint in Flash2.3 KB
Number of API files4
Timing budget range[15, 20, 33, 50, 100, 200, 500] ms
Fast ranging frequency66 Hz max.
Dynamic SPAD selectionYes
Default inter-measurement period100 ms
Default timing budget100 ms
Short distance mode max range1.3 m
Long distance mode max range4 m
Receiving SPAD array size16x16 SPADs

Frequently asked questions

What is the difference between the VL53L1X API and the VL53L1X ULD API?

The VL53L1X ULD API is an optimized version with a smaller code footprint (2.3 KB vs. 9 KB) and contains only four files instead of 35.

What are the available timing budget values for the VL53L1X ULD?

The available timing budget values are 15, 20, 33, 50, 100, 200, and 500 ms.

How do I stop the current ranging operation?

To stop the current ranging operation, the user must use the stop command, VL53L1X_Stop().

What is the maximum distance measurable in Short mode?

The maximum distance measurable in Short mode is limited to 1.3 meters.