This document describes how to use Arm® Cortex®‑M7 -based STM32H7 single-core series microcontroller unit (MCU) devices (further also referred to as Device(s)) in the context of a safety‑related system, specifying the user's responsibilities for installation and operation, in order to reach the desired safety integrity level.
This safety manual guides users in implementing STM32H7 single-core series microcontrollers within safety-related systems, targeting SIL2 for single devices and SIL3 for dual-device configurations. It outlines safety architecture, diagnostic requirements, and compliance with IEC 61508 standards. The document assumes software-based safety mechanisms and requires adherence to specified conditions of use for reliable operation.
The manual defines the 'Compliant item' as a system including one or two STM32 devices, connected to sensors, actuators, and external safety components like watchdogs and voltage monitors. It details safety functions performed by input, computation, and output processing elements, and clarifies roles of external diagnostics for achieving targeted safety integrity levels.
SIL2 for single devices and SIL3 for two distinct devices, with specific architectures and compliance to this manual.
A system including one or two STM32 devices, connected to sensors, actuators, and external safety components like watchdogs and voltage monitors.
IEC 61508, version IEC 61508-1-7 © IEC:2010.