This is a design manual that introduces integral abutment bridge structures
The manual defines integral abutment bridges as structures where the superstructure is cast integrally with the substructure, eliminating the need for conventional expansion joints. This design accommodates thermal expansion and contraction through flexible substructure piling, which reduces construction and maintenance costs. The document specifies that the connection between the abutment and superstructure is assumed to be pinned for design purposes, while the concrete abutment acts as a rigid mass.
| Minimum approach slab length | 3 m |
|---|---|
| Maximum skew angle | thirty (30) degrees |
| Minimum pile penetration | 6 m |
| Minimum wall thickness for pipe casings | 6 mm |
| Geotextile bedding minimum slope length | 2 m |
For bridge lengths over 50 m, unless the highway pavement is rigid concrete, provisions for expansion at the approach slab ends are required.
Integral abutments are not recommended for bridge lengths over 140 m at this time.