This document is the application manual for the TVD 1.3 Power Supply Module provided by INDRAMAT. The module can be directly connected to 3 x AC 380.480V mains power.
This manual details the applications, electrical connections, and installation guidelines for the Indramat TVD 1.3 power supply module. It covers power ratings, overload capabilities, and technical data for direct connection to 3 x AC 380...480V mains. The document also includes troubleshooting, terminal descriptions, and dimensional data for integration into control cabinets.
The TVD 1.3 provides regulated DC bus voltage, internal power contactors, and signal voltages for drive modules. It supports up to 12kW continuous mechanical output and includes features like dynamic braking, fault protection, and UL registration.
| Input Voltage | 3 x 380 ... 480 ( ± 10%) |
|---|---|
| Frequency | 50 ...60 Hz |
| DC Bus Voltage | 320 ( ± 5%) |
| Continuous DC Bus Power | 15 kW or 7.5 kW |
| Peak DC Bus Power (0.3s) | 45 kW or 22.5 kW |
| Ambient Temperature (Rated) | +5 ... +45 °C |
| Protection Category | IP 10 |
The TVD 1.3 accepts 3 x AC 380...480V (±10%) at 50...60Hz.
The TVD 1.3 provides 15 kW or 7.5 kW continuous DC bus power.
The maximum permissible ambient temperature for rated operation is +45°C.
The TVD 1.3 has an IP 10 protection category per DIN 40 050.