This is a project planning manual of DIAX02 DDS02.1/03.1 Drive Controller - Basic Unit
The document serves as a project planning guide for the Indramat DDS02.1/03.1 digital AC servo drive controller. It details the modular concept of combining AC servo and main drives with supply units to create compact drive packages suitable for machine tools, robotics, and handling machines.
Key sections include safety guidelines for electrical drives, technical data regarding power sections and energy loss, instructions for planning control cabinet construction, and detailed procedures for electrical connections including chassis earths, motor power cables, and various interface connectors.
| Supply Voltage | regulated DC 24V |
|---|---|
| Signal Voltages Range | 5 to 30 volts |
The DDS drive controller is used in conjunction with MDD, MKD, and LAR AC motors.
No, the DDS should not be operated with a TVM 1.2 supply unit because its DC 24V is not regulated.