NSL-F is a continuous level sensor for use in the food and biopharma industries. It can monitor the continuous level of highly viscous and pasty media, and is suitable for the measurement of foamy media. The sensor can be used for electrically conductive media, but is not suitable for explosive areas.
This document is the operating manual for the NSL NSL-F series continuous level sensors, designed for use in food and biopharmaceutical applications. The sensors are suitable for monitoring levels in metallic vessels up to 3 meters in height and are ideal for highly adhesive, pasty, and foamy media with a conductivity of at least 5 µS/cm. They feature a hygienic design and a four-conductor configuration with a 4...20 mA output signal.
| Maximum vessel height | 3 m |
|---|---|
| Minimum conductivity | 5 µS/cm |
| Output signal | 4...20 mA |
| Mounting orientation | Above, below, diagonally, or lateral |
No, the sensor is not suitable for explosive areas.
No, due to the potentiometric measuring principle, calibration is not required after a change in medium.
Yes, lateral installation is possible using an angulated sensor and various clamping systems for type NSL-F-01.