This manual introduces the features and specifications of the KEW SNAP series 2002PA/2002R digital clamp meters and provides detailed instructions on how to use them.
The KEW 2002PA and 2002R are digital clamp meters designed for measuring AC current, AC voltage, DC voltage, and resistance. The 2002R model features accurate true-RMS reading for distorted waveforms, while the 2002PA offers standard measurements. Both models provide a wide measuring range up to 2000A for current and include features such as data hold, sleep function, and output for chart recorders.
| Measuring Ranges (AC Voltage) | Auto-ranging |
|---|---|
| Measuring Ranges (DC Voltage) | Auto-ranging |
| Measuring Ranges (Resistance) | Auto-ranging |
| Frequency Range (AC Current) | 40Hz to 1kHz |
| Display | 4000 counts |
| Response Time | Approx. 2 seconds |
| Dimensions | 247 x 105 x 49 mm |
| Weight | Approx. 470g |
| Power Source | Two R6P batteries |
The instrument provides a wide measuring range from 0 up to 2000A.
Yes, it automatically powers down in about 10 minutes after the last switch operation.
The jaws can accommodate conductors with a diameter of approximately 54.5 mm max.