This is the instruction manual for the Kyoritsu 8128 Power Clamp Sensor, designed for use with power meters like the MODEL6300. It includes safety warnings, operating instructions, and technical specifications. The sensor is rated for AC 300V and measures current from 0 to 50A RMS. It features a clamp design for non-invasive current measurement and complies with IEC 61010 safety standards. Users must follow safety precautions to avoid injury or damage.
| Rated Voltage | AC 300V |
|---|---|
| Measuring Range | AC 0~50A rms (70.7A peak) |
| Accuracy | ±0.5% rdg + 0.1mV |
| Input Frequency | 50/60Hz |
| Output Terminal | MINI DIN 6PIN |
| Weight | Approx. 160g |
| Cable Length | Approx. 3m |
| Conductor Size | Approx. 24mm in diameter (max.) |
| Dimensions | 100 x 60 x 26mm |
The sensor measures up to 50A RMS (70.7A peak).
It complies with IEC 61010-2-032 and is rated CAT III 300V (Pollution Degree 2).
The output connector is MINI DIN 6PIN.