Intelis™ Gas Meter Technical Reference Guide
The Intelis GasMeter Technical Reference Guide from Itron covers the Intelis GasMeter line: the original Intelis GasMeter, Intelis 250 GasMeter, and Intelis 425 GasMeter. It is written for field dispatchers, utility personnel, and Itron internal users and describes meter functionality including measurement, communications, and the safety shutoff valve.
The guide lists product specifications, components, and RF communications, and explains ultrasonic measurement technology, data collection modes, installation, calibration, programming, events and alarms logging, and maintenance. Pressure sensing is not included in the Intelis GasMeter, is optional for the Intelis 250, and is standard on the Intelis 425.
| Meter capacity (Intelis GasMeter) | 250 CFH at ½ WC (water column) or 7.1 m3/h at 0.125 kPa |
|---|---|
| Meter capacity (Intelis 250 GasMeter) | 300 CFH at ½ WC or 8.5 m3/h at 0.125 kPa |
| Measurement principle | Ultrasonic time of flight |
| Accuracy (gas measurement) | Class 1 and ±0.5% at room temperature |
| Accuracy (pressure, Intelis 250 with pressure sensing) | ±1% full scale from -25°C to +55°C (-13°F to +131°F) |
| Meter type | Temperature compensated (TC) or non-temperature compensated (NTC) |
| Hub center-to-center | 6 inches (152.4 mm) |
The Intelis GasMeter line includes three variants.
It is 250 CFH at ½ WC (water column) or 7.1 m3/h at 0.125 kPa.
No. Pressure sensing is not included in the Intelis GasMeter; it is optional for the Intelis 250 and always included on the Intelis 425.
It uses ultrasonic time of flight.