This guide provides instructions for installing the Itron 100G high-powered gas encoder-receiver-transmitter (ERT) module on compatible meters from various manufacturers. The document covers transmission modes, specifications, and a list of compatible meter models.

What's inside

  • Transmission Modes
  • Specifications
  • Meter Compatibility List
  • American Meter Installation
  • Sensus Meter Installation
  • Installation Prerequisites
  • Materials Supplied By Itron
  • Materials Supplied By You
  • Preinstallation Preparations
  • Program the ERT Module

Specifications

Power SourceA cell lithium battery
Operating Temperatures-40° to 158° F (-40° to +70° C)
Operating Humidity5 to 95percent relative humidity
Program Frequency908 MHz
Transmit Frequency908 to 924 MHz
FCC CompliancePart 15 certified

Frequently asked questions

What are the two standard transmission modes for the 100G ERT?

The two modes are Fixed Network Mode, which transmits every 60 seconds, and Mobile and HandHeld Mode, which transmits every 15 seconds.

Is an FCC license required to read 100G ERT modules?

No, an FCC license is not required to read 100G ERT modules.

What materials are supplied by Itron for installation?

Itron supplies the 100G gas ERT modules and tamper plugs.