This is an immuno quantitative enzyme linked immunosorbent assay (IQELISA) kit for quantitative measurement of mouse Osteopontin in serum, plasma and cell culture supernatants. The assay employs an antibody specific for mouse Osteopontin coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and Osteopontin presence is detected by binding with the antibody. The immune complex is washed off and TaqMan® PCR reagents are added for real-time quantitative PCR detection.


RayBiotech Mouse Osteopontin IQELISA Kit User Manual - cover page
Brand
RayBiotech
Category
medical technology
Document type
User Manual
Language
English
Pages
11
File format
PDF
File size
160 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
78999120911D495FA83FEFF2FDD97AFD

About this manual

This document provides step-by-step instructions for using the RayBio® Mouse Osteopontin IQELISA Kit, which combines ELISA specificity with qPCR sensitivity. The assay uses a 96-well PCR plate coated with anti-Mouse Osteopontin antibody. Samples and standards are added, followed by detection reagents and PCR master mix. Data is collected via real-time PCR, and concentrations are calculated from Ct values. The kit includes reagents, storage instructions, and troubleshooting guidance.

The kit requires a real-time PCR instrument, precision pipettes, and standard dilution buffers. Standards are prepared in a 2000 pg/ml stock and diluted to create a 7-point standard curve. Samples are incubated with the plate, washed, and then incubated with detection reagents. After PCR setup and cycling, Ct values are used to calculate antigen concentration using a log-log graph or linear regression.

What's inside

  • Introduction
  • Reagents
  • Storage
  • Additional Materials Required
  • Reagent Preparation
  • Assay Procedure
  • Assay Procedure Summary
  • Calculation of Results
  • Troubleshooting Guide

Specifications

Minimum Quantifiable Dose0.49 pg/ml
Recovery Rate93%
Intraplate CVBelow 10%
Interplate CVBelow 15%

Frequently asked questions

What is the minimum quantifiable dose of Osteopontin in this kit?

The minimum quantifiable dose is typically 0.49 pg/ml.

What is the recovery rate for serum spike tests?

The recovery rate is 93%, with a range from 84% to 100%.

What PCR instrument is recommended?

A real-time PCR instrument is required, with Bio-Rad recommended.