H2scan HY-ALERTA 500 Handheld Hydrogen Leak Detector Operating Manual

HY-ALERTA™ 500 Handheld Hydrogen Leak Detector is a hydrogen leak detector produced by H2Scan company. It has high accuracy, high sensitivity and portability.


H2scan HY-ALERTA 500 Handheld Hydrogen Leak Detector Operating Manual - cover page
Brand
H2Scan
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
655 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
C49277C7C3036A5705578DF5E74EE985

About this manual

The H2scan HY-ALERTA 500 is a handheld hydrogen leak detector designed to locate and find hydrogen leaks as quickly as possible. It features two sensing elements on the same semiconductor die, allowing it to detect hydrogen leaks as low as 15 ppm and operate safely up to 100% hydrogen concentration. The device utilizes a flexible cable to allow the sensor probe access to virtually all potential leak sources.

What's inside

  • Description
  • Specifications
  • Startup
  • Shutdown
  • Battery Level
  • Normal Operation
  • Hydrogen Sensing Considerations
  • Bump Test
  • Verification
  • Troubleshooting

Specifications

Sensitivity Range0.0015% (15 ppm) to 100% hydrogen by volume
Response TimeIndication of hydrogen within seconds
Operating Temperature0°C to +40 °C
Storage Temperature-20°C to +45 °C
Battery Lifeover 10 hours of operation
Charging Time4 hours
Weight975 g (2.15 lb.)
Product Life Expectancy10 years

Frequently asked questions

What is the minimum hydrogen concentration the detector can find?

The HY-ALERTA 500 can detect hydrogen leaks as low as 15 ppm.

How long does it take to recharge the battery?

The internal rechargeable Lithium Ion battery is recharged in 4 hours with the included charger.

What does a solid amber LED on the probe tip indicate?

A steady H2 level is indicated by a solid amber light on the probe tip.