GOSSEN METRAWATT METRAVOLT 12D+L Voltage-Continuity Tester User Manual

This manual introduces the basic functions and operating steps of the GOSSEN METRAWATT METRAVOLT 12D+L Voltage-Continuity Tester.


GOSSEN METRAWATT METRAVOLT 12D+L Voltage-Continuity Tester User Manual - cover page
Brand
Gossen MetraWatt
Document type
User Manual
Language
English
Pages
11
File format
PDF
File size
149 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
6956F3D72D7CF92AC5F5C7A53F184EBA

About this manual

The METRAVOLT 12D+L is a two-pole voltage tester with digital display, designed for measuring AC and DC voltages from 24 V to 1000 V and continuity up to 1999 kΩ. It features safety indicators, LEDs, and a buzzer for voltage and continuity detection. The device is IP65 rated for use in precipitation and complies with DIN EN 61243-3. Safety precautions and self-test procedures are detailed to ensure correct and safe operation.

The manual covers battery use, display and function testing, voltage and polarity measurement, phase and phase sequence testing, and safety guidelines. It emphasizes the importance of checking the device before use and warns against misuse, which voids warranty. The device automatically switches off after 30 seconds of inactivity and has a 2-minute maximum on-time for voltage testing.

What's inside

  • Safety Precautions
  • Putting into Operation
  • Measuring and Testing
  • Voltage Testing
  • Continuity Testing
  • Phase and Phase Sequence Testing
  • Self-Test Procedure

Specifications

Voltage Range24 V to 1000 V AC / 1500 V DC
Continuity Range0 to 1999 kΩ
Protection RatingIP 65
Maximum On-Time2 minutes
Battery Type9 V block battery (IEC 6 LR 61)

Frequently asked questions

What is the voltage range of the METRAVOLT 12D+L?

It measures AC and DC voltages from 24 V to 1000 V, with a DC limit of 1500 V.

How long can the device operate continuously on voltage testing?

The maximum on-time is 2 minutes.

What does the red LED indicate?

It indicates hazardous voltage ≥ 50 V AC / 120 V DC, but not the actual measurement value.