Key facts
- Manuals
- 12
- Models
- 2
- Languages
- EN · DE · RO
- Last added
- 2026-11-01
Gossen MetraWatt models by category
Featured Gossen MetraWatt manuals

Gossen Metrawatt U1281/U1289/U1381/U1387/U1389 Main Distribution – Production Energy Meter Operating Manual
This manual provides operating instructions for Gossen Metrawatt's MID Electronic Active Energy Meters, including safety precautions, wiring instructions, pulse output settings, display functions, and parameter configuration. It details how to configure current and voltage transformers, set pulse rates, and interpret display symbols. The document also covers error codes, calibration procedures, and contact information for technical support and recalibration services.
The meters are designed for industrial energy measurement and feature configurable parameters for different applications. Safety warnings emphasize handling live components, proper wiring, and calibration procedures. The manual includes diagrams and tables for terminal connections, pulse output configurations, and display symbol meanings.
Covers: Safety Precautions · Serial Plate and Terminals · Pulse Output Configuration · Display and Control Panel · Parameter Configuration · Error Messages and Reset

Gossen Metrawatt METRALINE DM 61/62 Analog-Digital Multimeter Operating Instructions
This document provides operating instructions for the Gossen Metrawatt METRALINE DM 61 and DM 62 Analog-Digital Multimeters. Key features include automatic blocking sockets (ABS) to prevent incorrect connections, automatic or manual measuring range selection, and a dual digital display with an analog scale. The devices support measurements of voltage, current, resistance, capacitance, frequency, duty cycle, temperature, and continuity.
Covers: Features · Characteristic Values · Influencing Quantities · Power Supply · Electromagnetic Compatibility · Safety Requirements

GOSSEN METRAWATT METRISO 5000 A/AK High-Voltage Insulation Tester Operating Instructions
This document provides operating instructions for the METRISO 5000 A/AK High-Voltage Insulation Tester, which can be powered by batteries or an optional crank generator. The manual details safety precautions, initial start-up procedures including battery installation and testing, and the operation of the analog display and selector switches.
Covers: Safety Precautions · Applications · Initial Start-Up · Battery Installation · Testing the Batteries · Switching the Tester On and Off

GOSSEN METRAWATT METRAport 32 XS Digital Multimeter Operating Instructions
This document provides the operating instructions for the METRAport 32 XS Digital Multimeter manufactured by GOSSEN METRAWATT. It details safety features, initial start-up procedures, and the use of control elements such as the rotary switch, MAN/AUTO key, and multifunction keys. The manual explains how to select measuring functions and ranges, including automatic and manual modes for voltage, current, resistance, capacitance, frequency, and temperature.
Covers: Safety Features and Precautions · Initial Start-Up · Selecting Measuring Functions · Automatic Measuring Range Selection · Manual Measuring Range Selection · Voltage Measurement
Latest Gossen MetraWatt manuals
Gossen Metrawatt U1281/U1289/U1381/U1387/U1389 Main Distribution – Production Energy Meter Operating Manual
User Manual 16 pages · 383 KB · ENOperating instructions for Gossen Metrawatt's MID Electronic Active Energy Meters, covering safety, wiring, pulse output, display, and parameter configuration.
Gossen Metrawatt METRALINE DM 61/62 Analog-Digital Multimeter Operating Instructions
User Manual 4 pages · 160 KB · ENOperating instructions for the Gossen Metrawatt METRALINE DM 61 and DM 62 analog-digital multimeters, covering features, specifications, and safety.
GOSSEN METRAWATT METRISO 5000 A/AK High-Voltage Insulation Tester Operating Instructions
User Manual 12 pages · 408 KB · ENOperating instructions for the METRISO 5000 A/AK High-Voltage Insulation Tester, covering safety, setup, voltage and insulation resistance measurements, and…
GOSSEN METRAWATT METRAport 32 XS Digital Multimeter Operating Instructions
User Manual 28 pages · 278 KB · ENOperating instructions for the GOSSEN METRAWATT METRAport 32 XS Digital Multimeter, covering safety, setup, measuring functions, and maintenance.
Gossen Metrawatt R2400 Electronic Controller Operating Instructions
User Manual 34 pages · 827 KB · DEOperating instructions for the Gossen Metrawatt R2400 electronic controller covering installation, electrical connections, configuration, and technical data.
Gossen Metrawatt METRA HIT 27EX Milliohmmeter Operating Instructions
User Manual 36 pages · 395 KB · ENOperating instructions for the Gossen Metrawatt METRA HIT 27EX milliohmmeter designed for use in potentially explosive atmospheres.
Gossen Metrawatt Z270U USB PD Power Pack User Manual
User Manual 4 pages · 148 KB · ENUser manual for the Gossen Metrawatt Z270U USB PD Power Pack, covering safety, usage, technical specs, and disposal instructions.
Gossen Metrawatt R2500-3 Compact Controller Operating Instructions
User Manual 51 pages · 497 KB · ENOperating instructions for the Gossen Metrawatt R2500-3 compact controller and temperature limiter, covering installation, configuration, and operation.
Gossen Metrawatt METRALINE DM 61/62 Analog-Digital Multimeter Operating Instructions
User Manual 36 pages · 474 KB · ENOperating instructions for the Gossen Metrawatt METRALINE DM 61/62 analog-digital multimeter, covering safety, functions, measurements, and maintenance.
GOSSEN METRAWATT METRAVOLT 12D+L Voltage-Continuity Tester User Manual
User Manual 11 pages · 149 KB · ENUser manual for GOSSEN METRAWATT's METRAVOLT 12D+L voltage and continuity tester with safety, operation, and measurement instructions.
Gossen Metrawatt METRA HIT 27EX Milliohmmeter Operating Instructions
User Manual 36 pages · 4 MB · ENOperating instructions for the Gossen Metrawatt METRA HIT 27EX milliohmmeter for use in explosive atmospheres.
Gossen Metrawatt TRMS Digital Multimeter User Manual
User Manual 97 pages · 2 MB · ROUser manual for the Gossen Metrawatt TRMS digital multimeter covering safety, operation, measurement functions, and maintenance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Gossen MetraWatt manuals
What safety precautions should be taken when wiring the meter?
Ensure connector cables are not damaged and voltage-free while wiring. Disconnect input voltage if safe operation is no longer possible. Only trained personnel should work on live instruments.
How do I configure pulse output settings?
Pulse output settings are configurable based on model and features. For example, U1281/U1289 have fixed 1000 pulses/kWh, while U138x models allow programmable rates from 1 to 1000000 pulses/kWh.
What is the warranty period for this multimeter?
The device comes with a voluntary manufacturer's warranty of 36 months for material and workmanship.
From: Gossen Metrawatt METRALINE DM 61/62 Analog-Digital Multimeter Operating Instructions
How does the automatic blocking socket feature work?
Automatic blocking sockets prevent incorrect connection of measurement cables and inadvertent selection of the wrong measured quantity.
From: Gossen Metrawatt METRALINE DM 61/62 Analog-Digital Multimeter Operating Instructions
What batteries are required for the METRISO 5000 A/AK?
The device requires 6 commercially available 1.5 V type IEC R20 or IEC LR20 batteries or storage batteries.
From: GOSSEN METRAWATT METRISO 5000 A/AK High-Voltage Insulation Tester Operating Instructions
Can mains driven power packs be used with this tester?
No, mains driven power packs are not permissible because their use is life endangering.
From: GOSSEN METRAWATT METRISO 5000 A/AK High-Voltage Insulation Tester Operating Instructions
