This file is about small diameter filter scavenger installation and operation manual
This manual provides step-by-step instructions for installing, operating, and maintaining the Small Diameter Filter Scavenger (SDFS) system, including wiring, deployment, and troubleshooting. The system is designed for hydrocarbon recovery in wells and includes components like a product pump, floating intake cartridge, and optional water pump. It is compatible with Geotech Environmental Control Module (GECM) for control and monitoring.
The guide covers safety precautions, system components, wiring procedures for single-phase and three-phase power, probe installation, maintenance tasks like cleaning intake cartridges, and troubleshooting common issues such as power failures or water intrusion.
| Product Pump Voltage | 12VDC |
|---|---|
| Product Pump Decoupling Pressure | 95 PSI (6.5 bar) to 105 PSI (7.2 bar) |
| Product Reservoir Capacity | 1qt (.95 liter) |
| Intake Cartridge Mesh Sizes | 100 mesh (blue) and 60 mesh (green) |
The product pump is designed to decouple between 95 PSI (6.5 bar) and 105 PSI (7.2 bar), with a maximum pressure of 90 PSI (6.2 bar) to 95 PSI (6.5 bar) depending on viscosity.
The intake cartridge has a floating float with an oleophilic/hydrophobic screen that allows hydrocarbons to enter while repelling water, and it travels up and down a 1” x 36” water discharge pipe.
The water override conductivity sensor shuts down the product pump whenever water is detected inside the reservoir.
Wire a single-phase 115 or 230VAC SDFS with water pump and 12VDC product pump motors using the instructions in Section 2: System Installation.