ProFloSE Downflow Brining Service Manual

The file is a maintenance manual, which introduces the maintenance methods and precautions of the product


ProFloSE Downflow Brining Service Manual - cover page
Brand
ProFloSE
Category
Water heater
Document type
Service Manual
Language
English
Pages
36
File format
PDF
File size
799 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
BD3D6DFD5822D063CEDE13726B4B2E26

About this manual

This document is a service manual for the ProFloSE Downflow brining unit. It provides a job specification sheet for recording installation details such as tank sizes, media type, and capacity. The manual outlines general residential installation requirements, including water pressure limits (minimum 20 psi, maximum 120 psi), temperature limits (maximum 110 °F), and electrical needs.

What's inside

  • Job Specification Sheet
  • General Residential Installation Check List
  • Valve Installation and Start-up Procedures
  • Control Start-Up Procedures
  • Control Programming
  • Extra Cycle Button
  • Regeneration Cycle Displays
  • Control Operation During Regeneration

Specifications

Minimum inlet water pressure20 psi
Maximum water pressure120 p.s.i.
Maximum water temperature110 ° F
Minimum drain line pipe size1/2″
Lubricant type for sealsSilicone

Frequently asked questions

What is required for the electrical supply?

An uninterrupted alternating current (A/C) supply is required.

How do you enter the programming mode?

Push and hold for 5 seconds both the Up and Down Set Buttons.

Does the control require a battery backup?

No, the control programming is stored in memory permanently without the need for battery backup power.