This document is the maintenance manual for the Fleck 5000SE water softener.
This document serves as a service manual for the ProFloSE Fleck 5000SE downflow brining water softener. It outlines general residential installation checklists, including requirements for water pressure, electrical facilities, and existing plumbing conditions. The manual specifies that a minimum of 20 psi inlet water pressure is required for the regeneration valve to operate effectively, while water pressure must not exceed 120 p.s.i. and water temperature must not exceed 110°F.
| Minimum Inlet Water Pressure | 20 psi |
|---|---|
| Maximum Water Pressure | 120 p.s.i. |
| Maximum Water Temperature | 110°F |
| Drain Line Minimum Size | 1/2″ |
| Distributor Tube Size | 1″ |
A minimum of 20 psi inlet water pressure is required for the regeneration valve to operate effectively.
Teflon tape is the only sealant to be used on the drain fitting.