About this manual

This document serves as a service manual for the ProFloSE Fleck 5000SE downflow brining water softener. It outlines general residential installation checklists, including requirements for water pressure, electrical facilities, and existing plumbing conditions. The manual specifies that a minimum of 20 psi inlet water pressure is required for the regeneration valve to operate effectively, while water pressure must not exceed 120 p.s.i. and water temperature must not exceed 110°F.

What's inside

  • General Residential Installation Check List
  • Water Pressure Requirements
  • Electrical Facilities
  • Existing Plumbing
  • Location of Softener and Drain
  • By-Pass Valves
  • Valve Installation and Start-up Procedures
  • Drain Line Flow Control
  • Brine Tank Setup

Specifications

Minimum Inlet Water Pressure20 psi
Maximum Water Pressure120 p.s.i.
Maximum Water Temperature110°F
Drain Line Minimum Size1/2″
Distributor Tube Size1″

Frequently asked questions

What is the minimum water pressure required for operation?

A minimum of 20 psi inlet water pressure is required for the regeneration valve to operate effectively.

What sealant should be used on the drain fitting?

Teflon tape is the only sealant to be used on the drain fitting.

What lubricant is recommended for the distributor o-ring?

Only silicone lubricant should be used to lubricate the distributor o-ring seal.