Aqua Systems 9000/9100/9500 water softener service manual. This manual contains general installation and maintenance instructions for the water softener.
This manual provides service and installation instructions for Aqua Systems Model 9000, 9100, and 9500 water softeners. It details the general and commercial installation checklist, including requirements for water pressure, electrical facilities, and plumbing conditions. The document outlines specific procedures for setting up the regeneration cycle program, time brine refill, and ET Timer installation and start-up.
| Minimum Water Pressure | 25 lbs |
|---|---|
| Maximum Water Pressure | 125 psi |
| Maximum Water Temperature | 110°F |
| Minimum Drain Pipe Size | 1/2" |
| Regeneration Time (1/15 RPM) | 82 minutes |
| Regeneration Time (1/30 RPM) | 164 minutes |
A minimum of 25 lbs of water pressure is required for regeneration valve to operate effectively.
The number of pins in the backwash section multiplied by two equals the minutes of backwash.
The unit should not be subjected to water temperatures exceeding 110°F.