Aqua Systems 9000/9100/9500 Water Softener Service Manual
This manual provides service and installation instructions for Aqua Systems Model 9000, 9100, and 9500 water softeners. It details the general and commercial installation checklist, including requirements for water pressure, electrical facilities, and plumbing conditions. The document outlines specific procedures for setting up the regeneration cycle program, time brine refill, and ET Timer installation and start-up.
Covers: Job Specifications Sheet · General and Commercial Installation Checklist · Regeneration Cycle Program Setting Procedure · Time Brine Refill and Meter Setting Procedure · ET Timer Installation And Start-Up Procedures · 9000 Control Valve Assembly
Latest Aqua Systems manuals
Aqua Systems 9000/9100/9500 Water Softener Service Manual
Service Manual 56 pages · 2 MB · ENService manual for Aqua Systems 9000, 9100, and 9500 water softeners covering installation, timer settings, and troubleshooting.
Which document do I need?
Service Manual
Disassembly, diagnostics and part numbers, for repair.
Questions answered in Aqua Systems manuals
What is the minimum water pressure required for the unit to operate effectively?
A minimum of 25 lbs of water pressure is required for regeneration valve to operate effectively.
From: Aqua Systems 9000/9100/9500 Water Softener Service Manual
How do you calculate the backwash time on the program wheel?
The number of pins in the backwash section multiplied by two equals the minutes of backwash.