This is a manual for MODEL 9000 ECONOMINDER, which mainly introduces the product's specifications, functions and features
This document is a service manual for the ECONOMINDER 9000 water softener controller. It provides a job specification sheet for recording installation details such as water test results, tank sizes, and meter settings. The manual outlines the general installation checklist, including requirements for water pressure, electrical facilities, and plumbing conditions.
| Timer Type A Regeneration Time | 82 minute available regeneration time |
|---|---|
| Timer Type B Regeneration Time | 164 minute available regeneration time |
| Minimum Water Pressure | 25 pounds |
| Maximum Water Pressure | 120 p.s.i. |
| Maximum Water Temperature | 110 ° F |
| Electrical Supply | 110 volt, 60 Hertz |
| Meter Standard Range (3/4 inch) | 125 to 2,100 gal. |
| Meter Extended Range (3/4 inch) | 625 to 10,625 gal. |
| Meter Standard Range (1 inch) | 310 to 5,270 gal. |
| Meter Extended Range (1 inch) | 1,550 to 26,350 gal. |
A minimum of 25 pounds of water pressure is required for the regeneration valve to operate effectively.
The number of pins in the backwash section multiplied by two equals the backwash time in minutes.
The number of holes in the brine and rinse section multiplied by two equals the brine and rinse time in minutes.
The unit cannot be subjected to water temperatures exceeding 110 ° F.