Service Manual

Disassembly, diagnostics and part numbers, for repair.

Questions answered in ECONOMINDER manuals

What is the minimum water pressure required for the valve to operate?

The minimum water pressure required is 25 pounds.

From: ECONOMINDER 9500 Water Softener Service Manual

What is the minimum water pressure required for the MODEL 9500 to operate effectively?

A minimum of 25 pounds of water pressure is required.

From: ECONOMINDER 9500 Water Softener Service Manual

What is the flow range for the 2750RM model?

The 2750RM model has a flow range of 0.7 gpm to 40 gpm.

From: Econominder 2750RM 2850RM 3100RM 3900RM Remote Reset Meter Service Manual

How do I set the regeneration time for a delayed pulse meter?

Press and hold the red button to disengage the 24-hour gear, turn the gear to the desired time, and release the button to re-engage. To change the regeneration time, apply a new 24-hour label over the old one using the old label’s 2:00 a.m. mark as reference.

From: Econominder 2750RM 2850RM 3100RM 3900RM Remote Reset Meter Service Manual

How do you change the backwash duration on the ECONOMINDER Model 9000?

Change the backwash duration by adding or removing pins on the program disk; the number of pins multiplied by two equals the backwash time in minutes.

From: ECONOMINDER Model 9000 Service Manual

What is the power requirement for the ECONOMINDER Model 9000?

The unit requires a continuous supply of 110-120 volts AC at 60Hz.