This document introduces the features and usage methods of the SULFILTROS oil filter machine, including installation, operation and maintenance, and is suitable for liquid fuel, industrial lubricants and insulation filters.
The Sulfiltros SF oil filter press is designed for filtering liquid fuels, industrial lubricants, and insulators. The equipment consists of a metal structure, motor-pump, filter press, reservoir, and control box, with optional accessories available. It operates by suctioning oil from a storage tank through a gear pump (B1) into the filter press and reservoir. The filtered oil level is controlled by a float (4) that activates and deactivates the pump based on minimum and maximum levels. Unfiltered oil bypasses the plates and returns to the storage tank via gravity or an automatic return cycle.
The manual covers installation requirements, such as ensuring the equipment is leveled and connected to the correct voltage. It details the operation sequence, including checking pump rotation direction and setting the control to automatic mode. Maintenance procedures emphasize replacing the disposable filter paper (approx. 5 microns) every 50,000 liters of diesel or when pressure exceeds 30 psi above the initial reading. Troubleshooting guides address issues like pump failure, leaks, and flow loss. This manual is written in Portuguese.
| Filter paper porosity | 5 microns |
|---|---|
| Filter paper replacement interval | 50.000 liters |
| Pressure limit for filter change | 30 psi above initial |
| Maximum suction distance | 15 meters |
Replace the filter paper every 50,000 liters of diesel filtered or when the pressure gauge indicates 30 psi above the initial pressure.
The maximum recommended linear suction distance is 15 meters to ensure perfect operation.
The level is controlled by a float (4) that turns the pump on at the minimum level and off at the maximum level.