The document is about the operating manual of SULFILTROS Ex d mb IIA T6 Gb oil filter machine.
This manual provides instructions for installing, operating, and maintaining SULFILTROS oil filter machines. It includes details on components like the gear pump, filter plates, and manometer, as well as safety precautions and maintenance schedules. The document also addresses troubleshooting common issues and provides technical specifications and dimensions for various models.
The machines are designed for filtering liquids such as fuels and lubricants, with features like automatic level control and explosion-proof protection (Ex d mb IIA T6 Gb). Maintenance includes regular filter paper replacement and reservoir drainage to ensure optimal performance and safety. This manual is written in Portuguese.
| Protection Rating | Ex d mb IIA T6 Gb |
|---|---|
| Filter Paper Porosity | Approximately 5 microns |
| Maximum Operating Pressure | 30 psi above initial pressure |
| Recommended Filter Replacement Interval | Every 50,000 liters of filtered diesel |
| Maximum Suction Distance | 15 meters |
The maximum suction distance is 15 meters.
The filter paper should be replaced every 50,000 liters of filtered diesel, or sooner if the manometer indicates 30 psi above initial pressure.
The protection rating is Ex d mb IIA T6 Gb.
Check if the voltage is reaching the control box, if it is different from the specified voltage, if the contactor coil is burned, or if there is a loose wire.