This document is the communication function manual of the FAS-D200 series servo motor, which mainly introduces RS-485 communication protocol, communication frame structure, library function configuration and other content
This document serves as a User Manual for the Communication Function of the Ezi-STEP FAS-D200 series servo motor drive. It details the RS-485 communication protocol (Version 6), including frame structures, CRC calculations, and error handling for controlling up to 16 axes via a Daisy-Chain link.
The guide provides comprehensive information on the PC Library (DLL) for program development, covering functions for parameter control, servo control, I/O management, position control, and drive status monitoring. Additionally, it includes a section on the protocol for PLC programs, offering a test procedure to assist with custom protocol programming.
| Max Cabling Length | 30 m |
|---|---|
| Number of Connected Axis | 16 axis |
| Communication Type | Asynchronous Half-duplex |
| Baudrate | 19200 to 921600 bps |
| Data Type | 8bit ASCII Code, HEX |
| Stop Bit | 1bit |
| CRC Check | Yes |
The Ezi-STEP Plus-R can control up to 16 axes.
The system uses 'X16+X15+X2+1' for CRC-16-IBM.
A status code of 130 indicates a Data error, ROM data read/write error, or that the responded data value is out of the given range.
The minimum cable length between drives must be more than 60 cm.