Instruction manual, introducing how to use Ezi-SERVOII-EC driver, including downloading driver, setting InitFileEditor and other contents
This Korean basic usage guide describes setting up the FASTECH Ezi-SERVOII-EC EtherCAT servo drive with SoftServo 'WMX'. It begins with downloading the ESI(XML) file and the manual from the FASTECH website, then copying the XML file into the InitFileEditor ConfigFiles folder under the WMX installation path.
The guide then walks through InitFileEditor: selecting the FASTECH product, adding modules, editing the PDO mapping with the required inputs and outputs and defining offsets. A final section covers the EtherCAT Network Configurator, where the drive is connected and scanned, product information such as Vendor ID, Product Code and AL State is checked, and SDO values are read or changed and stored to EEPROM using Store Parameters (1010h). This manual is written in Korean.
| Required input PDOs | Status Word, Position Actual Value |
|---|---|
| Required output PDOs | Control Word, Target Position |
From the FASTECH website (www.fastech.co.kr), in the FASTECH data room.
Status Word and Position Actual Value as inputs, and Control Word and Target Position as outputs; Digital Inputs and Outputs are added to use the drive's I/O.
The Store Parameters (1010h) procedure is needed to save the changed object to EEPROM.