This carbon monoxide alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas.
The SimpliSafe SSCO3-0 is a carbon monoxide detector designed for residential indoor use to detect CO from combustion sources. It is not a smoke alarm and does not detect fire or other gases. The device requires a continuous power supply and three AA batteries, featuring a sensor that triggers an audible and visual alarm when dangerous CO levels are detected.
| Sensor Type | Electrochemical carbon monoxide sensor |
|---|---|
| Audible Alarm Level | Over 85dB at 3m |
| Response Time (70 PPM) | 60-240 min |
| Response Time (150 PPM) | 10-50 min |
| Response Time (400 PPM) | 4-15 min |
| Operating Temperature | 40 to 100°F (4.4 to 37.8°C) |
| Relative Humidity | 10 to 95% noncondensing |
| Battery Requirement | Three AA batteries |
| UL Rating | ANSI/UL 2034 |
Press the mute button, call emergency services, and immediately move to fresh air. Do not reenter until emergency services have arrived.
No, do not install it in garages, kitchens, or furnace rooms as these locations may cause nuisance alarms or damage.
You should perform a CO alarm test once a week to ensure it is functioning properly.
The yellow LED will flash four times a minute and the buzzer will chirp once a minute, indicating the unit needs replacement.