Elmo Motion Control SimplIQ Servo Drives CANopen DSP 402 Implementation Guide

Introduces the implementation method of SimplIQ servo drive in CANopen network.


Elmo Motion Control SimplIQ Servo Drives CANopen DSP 402 Implementation Guide - cover page
Brand
Elmo Motion Control
Category
Automation control Equipment
Document type
Programming Manual
Language
English
Pages
116
File format
PDF
File size
1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
7DC5476B2C5CF5EB23BCDBD68B892565

About this manual

The guide describes the objects and operational modes of the Elmo DSP-based motion controller implementation of the CiA DSP 402 protocol. It uses the Elmo Harmonica digital servo drive, part of the SimplIQ family, as its main example.

It states that the DSP 402 implementation applies to Elmo position unit modes UM=4 or UM=5, and that relevant motion commands must be given through DSP 402 only when working with the protocol. Other command sources are described as useful for monitoring and for functions outside DSP 402.

What's inside

  • Introduction
  • The DSP 402 Object Dictionary
  • Emergencies
  • Common Entries
  • Device Control
  • Modes of Operation
  • Factors
  • Homing
  • Position Control Function
  • Profiled Torque Mode

Specifications

Applicable Elmo unit modesUM=4 or UM=5

Frequently asked questions

What does this document describe?

It describes the objects and operational modes of the Elmo DSP-based motion controller implementation of the CiA DSP 402 protocol.

Which drive is used as the main example?

The Elmo Harmonica digital servo drive is used as the main example.

Which Elmo unit modes does the DSP 402 implementation apply to?

It applies to Elmo position unit modes UM=4 or UM=5.

How must relevant motion commands be given when working with DSP 402?

They must be given through this method only; other command sources may prevent proper operation according to the protocol.