Handling Precautions and Guideline for Lithium Ion (LO) batteries
This document outlines general precautions and specific handling guidelines for DYNAMIS Lithium Ion (LO) batteries. It emphasizes the importance of adhering to specified operating conditions to prevent damage and ensure safety. Key areas covered include charging parameters, discharge limits, and the use of Protection Circuit Modules (PCMs).
| Maximum charge voltage | 4.2 V per cell |
|---|---|
| Over-discharge cut-off voltage | 2.5 Vpc |
| Soldering temperature limit | 80 °C |
The recommended maximum charge voltage is 4.2 V per cell.
No, reverse charging is strongly prohibited as it may cause serious damage to the cell.
The protection function should prevent the voltage from dropping below 2.5 Vpc to avoid damage.