Dynamis LF Batteries Handling Precautions and Guideline

This document describes the handling precautions and guidelines for Dynamis lithium iron phosphate batteries.


Dynamis LF Batteries Handling Precautions and Guideline - cover page
Brand
Dynamis
Category
Other
Document type
User Manual
Language
English
Pages
3
File format
PDF
File size
26 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
A064BA31F48E128D8526B925285AC3DB

About this manual

This document provides essential handling precautions and guidelines for DYNAMIS Lithium Iron Phosphate (LF) batteries. It outlines critical safety measures regarding charging and discharging limits, temperature ranges, and the use of Protection Circuit Modules (PCM) to ensure optimal performance and safety.

What's inside

  • General
  • Charge
  • Discharge
  • Protection Circuit Module
  • Storage
  • Handling Advice
  • Battery pack design
  • Battery pack assembly
  • Further

Specifications

Maximum recommended charge voltage3.65 V per cell
Maximum charge voltage limit3.8 Vpc
Over-discharge cut-off voltage2.3 Vpc
Re-charge threshold for low voltage3.1 V
Maximum soldering temperature80 °C

Frequently asked questions

What is the maximum recommended charge voltage for DYNAMIS LF cells?

DYNAMIS recommends a maximum charge voltage of 3.65 V per cell.

At what voltage should a cell be recharged if the voltage is too low?

Re-charge is recommended if the cell voltage drops below 3.1 V.

Is the use of a Protection Circuit Module (PCM) required?

The use of a PCM is recommended for all types of LF batteries to protect the cell and enable best performance.

What temperature limit applies to soldering wires directly on LF contacts?

Soldering or welding directly on LF contacts must avoid temperatures above 80 °C to prevent cell damage.

Download PDF (26 KB)