This is a relay. The main features are single function, single range, single voltage, manual reset, cycle progress display, and 1, 2, or 3 changeover contacts with a maximum current of 16 A / contact.
The Crouzet 882569 is a manual reset relay with mono-function, mono-range, and mono-voltage operation. It features 1, 2, or 3 changeover contacts rated at 16A per contact. The relay is designed for industrial timing applications with a maximum timing of 30 minutes and a precision limit error of ±4%. It can be mounted using screws and has an IP10 terminal protection rating. The relay supports voltage variations up to ±15% and operates within a temperature range of -5°C to +70°C.
The product includes inverters for DC supply (24-48V and 110-127V) as accessories. It has a mechanical life of over 10^7 operations and a thermal rating of 20A. The relay is protected against vibration and has dielectric test voltage of 1000V according to IEC 255-5 or VDE 0435 standards.
| Breaking Capacity per Contact | 16 A |
|---|---|
| Maximum Available Timing | 30 min |
| Precision Limit Error | ±4 % |
| Thermal Rating | 20 A |
| Mechanical Life | > 10^7 operations |
| Operating Temperature Range | -5°C to +70°C |
| Storage Temperature Range | -40°C to +80°C |
| Dielectric Test Voltage | 1000 V |
| Insulation Class | VDE 0110 group C |
| Weight | 225 / 245 g |
The maximum available timing is 30 minutes.
The breaking capacity per contact is 16A.
The operating temperature range is -5°C to +70°C.
The dielectric test voltage is 1000V according to IEC 255-5 or VDE 0435 standards.