dc-ii™ drop-cell is a dual element silver/silver chloride (ag/agCl) reference electrode for measuring cathodic protection potential, which can be used to measure metal structures such as platforms and pipelines. calibration is required before use
The DC-II™ drop-cell is a dual element silver/silver chloride (Ag/AgCl) reference electrode designed for measuring cathodic protection potentials in seawater. It features twin reference electrodes that provide online calibration and a slim, weighted body to prevent entanglement during deployment off platforms or vessels. Readings are taken using a hand-held multi-meter.
| Electrode Type | Dual element silver/silver chloride (Ag/AgCl) |
|---|---|
| Application | Measuring cathodic protection potentials in seawater |
| Calibration Tolerance | Plus or minus 10.0mV |
| Zinc Coupon Reading Range | -1.030 V to -1.070 V |
They must be inspected yearly as part of Level I inspections per API RP 2A-WSD.
Check for a severed cable above the waterline or a gas bubble trapped in the drop cell chamber.
Visually inspect the cable for nicks with exposed wire or check for a bad ground on the structure.