Featured Deepwater Corrosion Services manuals

Deepwater Corrosion Services DC-II Drop Cell Operation Manual
The DC-II™ drop-cell is a dual element silver/silver chloride (Ag/AgCl) reference electrode designed for measuring cathodic protection potentials in seawater. It features twin reference electrodes that provide online calibration and a slim, weighted body to prevent entanglement during deployment off platforms or vessels. Readings are taken using a hand-held multi-meter.
Covers: Overview · Scope · Equipment requirements · Calibration instructions · Measurement · Normal cathodic protection ranges
Latest Deepwater Corrosion Services manuals
Deepwater Corrosion Services DC-II Drop Cell Operation Manual
User Manual 12 pages · 1.9 MB · ENOperation manual for the DC-II drop cell, a dual element silver/silver chloride reference electrode for measuring cathodic protection potentials in seawater.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Deepwater Corrosion Services manuals
How often must platforms and risers be inspected via drop cell in the Gulf of Mexico?
They must be inspected yearly as part of Level I inspections per API RP 2A-WSD.
From: Deepwater Corrosion Services DC-II Drop Cell Operation Manual
What action is required if the drop cell reads 0V?
Check for a severed cable above the waterline or a gas bubble trapped in the drop cell chamber.
From: Deepwater Corrosion Services DC-II Drop Cell Operation Manual