This manual provides Operating, Organizational and Direct Support Maintenance Instructions (Including Repair Parts and Special Tools List) for CONVERTER ASSEMBLY, VAPOR RECOVERY PART NUMBER F428A NSN 2590-01-090-7659.
This is a U.S. Army technical manual for the F428A Vapor Recovery Converter Assembly, used to collect vapors and control fuel levels during tank filling. It includes operator, organizational, and direct support maintenance instructions, troubleshooting procedures, and maintenance parts lists. The manual covers equipment characteristics, component functions, safety precautions, and operational principles, with detailed diagrams and step-by-step maintenance procedures.
| Operating Temperature | -65°F to +160°F |
|---|---|
| Operating Pressure | 120 psig |
| Flow Rating | 300 gpm |
| Fluid Temperature | -65°F to +135°F |
| External Leakage | Zero |
| Diameter with Levers Open | 20 inches maximum |
| Diameter at Base | 9.75 inches |
| Height | 15 inches maximum |
| Weight | Approximately 40 pounds |
120 psig.
Depress the drain button in the top of the converter assembly for 10 seconds minimum.
15 inches maximum.
Approximately 40 pounds.