This is a safety manual for multimeters
This document is the instruction manual for the Martindale Electric MM39 multimeter. It provides essential safety information, including warnings about hazardous voltages and the importance of inspecting the meter and test leads before use. The manual details the operating procedures for various measurement functions such as voltage, current, resistance, diode testing, and continuity checks.
| Display | 3½ digit liquid crystal display (LCD) |
|---|---|
| Measurement rate | 2 times per second |
| Power source | 1.5V batteries x2, R03/SIZE AAA |
| Dimensions | 145mm (H) × 70mm (W) × 34mm (D) |
| Weight | Approx. 11.1 oz. (315g) |
| DC VOLTS Accuracy (200mV) | ±(1.0% rdg + 2 dgts) |
| AC VOLTS Accuracy (200mV) | ±(2.0% rdg + 5 dgts) |
| Current Ranges | 10A |
The auto power off feature lasts for approximately 10 minutes.
The meter requires a 10A/500V fast acting ceramic fuse.
The accuracy is ±(5.0% rdg + 5 dgts) on the 20MΩ range.