About this manual

This manual provides instructions for the MTL10 and MTL20 test lamps, which are two-pole voltage indicators designed for universal applications. The devices feature bright LED indication for AC and DC voltage tests up to 500V AC and 750V DC, respectively, and include a full voltage indication function without batteries. The MTL20 model additionally features push button switches to test for interference (phantom) voltage.

What's inside

  • Safety Information
  • Introduction
  • Operation
  • Maintenance
  • Warranty
  • Measurement Categories
  • Specifications

Specifications

AC Voltage Test Limit500V
DC Voltage Test Limit750V
Measurement Category CAT IV600V to earth
Measurement Category CAT III1000V to earth
Environmental ProtectionIP64
Operating Duty Ratio8 to 1

Frequently asked questions

What is the operating duty ratio for the MTL10/MTL20?

The operating duty ratio is 8 to 1, meaning the device should be operated for a maximum of 30 seconds followed by a recovery period of 4 minutes.

How can I check if the test lamp is functioning correctly?

Before and after use, verify the voltage indicator is functioning correctly with a proving device (PD430 or PD440) or a known good voltage source.

What is the purpose of the push button switches on the MTL20?

The push button switches provide additional load to the circuit under test to help detect interference (phantom) voltage.