This manual introduces Detcon Model IR-700 combustible gas sensor, including sensor design, performance characteristics, installation, operation and maintenance.
This manual provides detailed instructions for installing, operating, and maintaining the Detcon IR-700 combustible gas sensor. It covers sensor electronics, mechanical design, field wiring, programming, calibration, and troubleshooting. The sensor uses non-dispersive infrared (NDIR) technology to detect hydrocarbon gases and features automatic calibration via LED display and magnetic programming tool. It is designed for explosion-proof environments and includes RS-485 and 4-20mA outputs.
The sensor is modular, with a replaceable IR sensor element and intelligent transmitter module. It is resistant to poisoning and can operate without oxygen. Calibration intervals are typically quarterly to annual, depending on field conditions. The unit includes a 4-character LED display and supports Modbus™ protocol for integration into control systems.
| Detection Range | 0-100% LEL or 0-50% LEL |
|---|---|
| Output | 4-20mA and Modbus™ RS-485 |
| Warranty | 5-year pro-rated warranty |
The sensor features automatic calibration via AutoZero and AutoSpan modes, guided by fully scripted instructions on the LED display.
The sensor comes with a 5-year pro-rated warranty.