PLANTOWER PMSA003I Digital Universal Partical Concentration Sensor Data Sheet

This is a product data manual of PMSA003I digital universal particle concentration sensor, which introduces the main characteristics, working principle, functional modules and other information of the sensor.


PLANTOWER PMSA003I Digital Universal Partical Concentration Sensor Data Sheet - cover page
Brand
Plantower
Document type
Datasheet
Language
Chinese
Pages
14
File format
PDF
File size
1.2 MB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
F1E0563C40CAC9F7D791562798793C8E

About this manual

The PLANTOWER PMSA003I is a digital universal particle concentration sensor that measures airborne particle concentration using laser scattering and MIE theory. It outputs data via I2C interface, providing particle counts and mass concentrations across multiple size ranges. The sensor operates on 5V DC, has a 38×35×12mm physical size, and supports both active and passive output modes. It is designed for indoor environmental monitoring and includes endurance testing for temperature, humidity, and power variations.

The sensor features a minimum detectable particle size of 0.3μm, real-time response, and high anti-interference performance due to its six-sided shielding structure. It can be integrated into environmental monitoring systems or air quality equipment to provide accurate particle concentration data. This manual is written in Chinese.

What's inside

  • Working Principle
  • Technical Specifications
  • Pin Definitions
  • Output Characteristics
  • Installation Considerations
  • Endurance Testing
  • I2C Interface Protocol
  • Register Definitions

Specifications

Measurement Range0.3~1.0; 1.0~2.5; 2.5~10 μm
Particle Counting Efficiency50%@0.3 μm, 98%@>=0.5 μm
Particle Effective Range (PM2.5)0~500 μg/m³
Particle Maximum Range (PM2.5)≥1000 μg/m³
Particle Resolution1 μg/m³
Power Supply5.0V (4.5V–5.5V)
Active Current≤100 mA
Working Temperature Range-10~+60 ℃
Working Humidity Range0~99%
Physical Size38×35×12 mm

Frequently asked questions

What is the minimum detectable particle size?

The minimum detectable particle size is 0.3 micrometers.

What is the power supply requirement?

The sensor requires a 5V DC power supply, with a voltage range of 4.5V to 5.5V.

What is the maximum error for PM2.5 measurements?

The maximum error is ±10% for 100–500 μg/m³ and ±10 μg/m³ for 0–100 μg/m³.