The Plantower PMS7003 data manual provides specifications, pin definitions, operating principles, and installation guidelines for the digital universal…
The PMS7003 is a digital universal particle concentration sensor that measures suspended particle numbers in the air and outputs the data via a digital interface. It uses a laser scattering principle to calculate particle size distribution based on MIE theory.
The manual includes technical specifications, pin definitions, typical circuit diagrams, consistency and endurance test results, power supply requirements, and detailed installation and circuit attention notes to ensure reliable operation in various environments.
| Minimum distinguishable particle diameter | 0.3 µm |
|---|---|
| Counting Efficiency | 50% @0.3 µm, 98% @≥0.5 µm |
| Effective Range (PM2.5) | 0~500 µg/m³ |
| Maximum Range (PM2.5) | ≥1000 µg/m³ |
| Resolution | 1 µg/m³ |
| Single Response Time | <1 s |
| Total Response Time | ≤10 s |
| DC Power Supply | 5.0 V typ, 4.5 V min, 5.5 V max |
| Active Current | ≤100 mA |
| Standby Current | ≤200 µA |
| Interface Level | L <0.8 V, H >2.7 V at 3.3 V |
| Working Temperature Range | -10 °C to +60 °C |
| Working Humidity Range | 0%–99% |
| Storage Temperature Range | -40 °C to +80 °C |
| MTTF | ≥3 years |
| Physical Size | 48 × 37 × 12 mm |
| Maximum Consistency Error (PM2.5) | ±10% @100~500 µg/m³ |
The sensor uses a laser scattering principle: a laser irradiates suspended particles, the scattered light is collected, and particle size distribution is calculated by a microprocessor based on MIE theory.