This manual provides safety instructions, maintenance guidelines, and usage specifications for the TDK-Lambda Vega 750 power supply module. It emphasizes that the unit is not customer-serviceable and must be installed by qualified personnel within host equipment. The manual includes warnings about high voltage, proper earthing, and environmental conditions. It also details disposal requirements and compliance with EMC directives for final installation.
The Vega 750 is designed for industrial use in Pollution Degree 2, overvoltage category II environments. It contains Material Group IIIb PCBs and must not be operated as a standalone device. The unit must be mounted with proper ventilation and cannot be inverted or mounted vertically with airflow downwards.
| Environmental Rating | IPX0, Pollution Degree 2, Overvoltage Category II |
|---|---|
| PCB Material Group | IIIb |
| Maximum Output Power | Not to exceed label rating |
| EMC Directive Scope | Not within scope; compliance required in final installation |
No, these products are not customer serviceable. Only TDK-Lambda UK LTD. and their authorised agents may carry out repairs.